Laser light spot analyzer

SKU: TH-360
The laser spot analyzer is mainly used for imaging the light spots emitted by a light source, displaying the light intensity at different positions of the spot in different colors. This allows designers to intuitively see the size, shape, and light intensity distribution of the spot, so they can adjust the design to improve spot quality. The analyzer's sensor measures wavelengths from 190nm to 1100nm, making it suitable for testing light spots in ultraviolet, visible, and infrared light.
0.0 (0 Reviews)
0 Sold
$299.99 $249.99
Received successfully
Coupon Code
CONTINUE SHOPPING
Quantity:
-
+
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
1/1
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Laser light spot analyzer
  • Description
Technical Parameters:
1. Sensor: CCD
2. Wavelength Range: 190 - 1100nm
3. Resolution: 720*576
4. Pixel Size: 5*6.25μm
5. Measurement Accuracy: 6.25μm
6. Minimum Spot Size: 5*6.25μm
7. Maximum Spot Size: 3595*3595μm (larger customizable)
8. Minimum Light Intensity: 1μw/cm²
9. Saturation Light Intensity: 100μw/cm² (attenuation required if exceeded)
10. Sampling Frequency: 25 frames/sec
11. Output Interface: USB 2.0
12. Operating Power: USB - 5V
13. USB Cable Length: 2m
14. Dimensions: 50*50*53mm
15. Lens Interface: φ25.4mm Pitch 0.79375
16. Bottom Screw: G1/4 Camera Screw (Imperial)





Frequently Asked Questions:

1. Maximum power: Under 200mW can be measured directly without damaging the laser; for above 200mW, attenuation is required.
2. Attenuation plates: The instrument comes with two attenuation plates, with transmittance of 1% and 0.25% each (optional: transmittance of 10%, 20%, 50%, 80%).
3. Entire spot is white: If the entire spot appears white in the software, it means overexposure. If only measuring spot size and shape, it does not matter. If checking uniformity, an attenuation plate should be added to minimize the white areas.
4. Measurement distance: Ensure the projected spot on the sensor is smaller than 3.5*3.5mm; the distance is not limited.
5. Which spots can be tested: Light sources with wavelengths ranging from 190 - 1100nm can be measured, including ultraviolet spots, infrared lasers, and visible light spots.
6. No data displayed in the lower right corner: Click the menu bar 'View' and check 'Calcult'.
Frequently Bought Together
more
Frequently Bought Together

CUSTOMER REVIEWS

0.0 0 Reviews
Write a review
$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00